Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV
dc.citation.firstpage | P09009 | en_US |
dc.citation.journalTitle | Journal of Instrumentation | en_US |
dc.citation.volumeNumber | 8 | en_US |
dc.contributor.author | Adair, A. | en_US |
dc.contributor.author | Akgun, B. | en_US |
dc.contributor.author | Ecklund, K.M. | en_US |
dc.contributor.author | Geurts, F.J.M. | en_US |
dc.contributor.author | Li, W. | en_US |
dc.contributor.author | Padley, B.P. | en_US |
dc.contributor.author | Redjimi, R. | en_US |
dc.contributor.author | Roberts, J. | en_US |
dc.contributor.author | Zabel, J. | en_US |
dc.date.accessioned | 2015-07-14T16:10:35Z | en_US |
dc.date.available | 2015-07-14T16:10:35Z | en_US |
dc.date.issued | 2013 | en_US |
dc.description.abstract | The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of √s = 7 TeV with integrated luminosities of about 5\fbinv. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity |η| < 0.8) and is 2–5% elsewhere. The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the endcaps. The calibration of the absolute energy is determined from Z→e+e− decays to a precision of 0.4% in the barrel and 0.8% in the endcaps. | en_US |
dc.identifier.citation | Adair, A., Akgun, B., Ecklund, K.M., et al.. "Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV." <i>Journal of Instrumentation,</i> 8, (2013) IOP Publishing: P09009. http://dx.doi.org/10.1088/1748-0221/8/09/P09009. | en_US |
dc.identifier.doi | http://dx.doi.org/10.1088/1748-0221/8/09/P09009 | en_US |
dc.identifier.uri | https://hdl.handle.net/1911/80962 | en_US |
dc.language.iso | eng | en_US |
dc.publisher | IOP Publishing | en_US |
dc.rights | This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | en_US |
dc.title | Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV | en_US |
dc.type | Journal article | en_US |
dc.type.dcmi | Text | en_US |
dc.type.publication | publisher version | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 1748-0221_8_09_P09009.pdf
- Size:
- 2.9 MB
- Format:
- Adobe Portable Document Format
- Description: