Through-bolt push out effects on the behavior of hybrid masonry systems
dc.citation.firstpage | 47 | en_US |
dc.citation.journalTitle | Engineering Structures | en_US |
dc.citation.lastpage | 53 | en_US |
dc.citation.volumeNumber | 97 | en_US |
dc.contributor.author | Nistor, Mihaela | en_US |
dc.contributor.author | Gao, Zhenjia | en_US |
dc.contributor.author | Stanciulescu, Ilinca | en_US |
dc.date.accessioned | 2015-06-15T18:57:49Z | en_US |
dc.date.available | 2015-06-15T18:57:49Z | en_US |
dc.date.issued | 2015 | en_US |
dc.description.abstract | This paper provides specifications necessary for designing hybrid masonry systems that resist through-bolt push out effects. Hybrid masonry is a relatively new structural system that can be used in seismic areas and comprises masonry panels connected to frames through steel plate connectors. However, masonry break-out at the connection between the steel plates and the masonry panel requires further analysis to better understand the load transfer mechanism of the hybrid masonry system. Therefore, we use a computational framework to model the hybrid masonry that uses a typical plasticity model with hardening for the steel components and a nonlocal two-scalar damage model that accounts for tension and compression for the masonry panel. Based on parametric studies conducted using this framework we provide recommendations for the through-bolt location and for the reinforcement percentage and location within the masonry panel to achieve best results in the load transfer mechanism of the hybrid masonry system during a seismic event. | en_US |
dc.identifier.citation | Nistor, Mihaela, Gao, Zhenjia and Stanciulescu, Ilinca. "Through-bolt push out effects on the behavior of hybrid masonry systems." <i>Engineering Structures,</i> 97, (2015) Elsevier: 47-53. http://dx.doi.org/10.1016/j.engstruct.2015.03.048. | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/j.engstruct.2015.03.048 | en_US |
dc.identifier.uri | https://hdl.handle.net/1911/80757 | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.rights | This is an author's peer-reviewed final manuscript, as accepted by the publisher. The published article is copyrighted by Elsevier. | en_US |
dc.subject.keyword | hybrid masonry system; | en_US |
dc.subject.keyword | yhrough-bolt | en_US |
dc.subject.keyword | nonlocal-damage model | en_US |
dc.title | Through-bolt push out effects on the behavior of hybrid masonry systems | en_US |
dc.type | Journal article | en_US |
dc.type.dcmi | Text | en_US |
dc.type.publication | post-print | en_US |