Stiffening Ring Design for Prevention of Storm-Surge Buckling in Aboveground Storage Tanks

dc.citation.articleNumber04019002en_US
dc.citation.issueNumber3en_US
dc.citation.journalTitleJournal of Structural Engineeringen_US
dc.citation.volumeNumber145en_US
dc.contributor.authorKameshwar, Sabarethinamen_US
dc.contributor.authorPadgett, Jamie E.en_US
dc.date.accessioned2019-08-21T19:16:16Zen_US
dc.date.available2019-08-21T19:16:16Zen_US
dc.date.issued2019en_US
dc.description.abstractThis paper proposes the use of an additional stiffening ring to prevent buckling of aboveground storage tanks (ASTs) under storm-surge inundation and presents an approach to obtain an optimal design for the additional ring. This study addresses the lack of methods to prevent storm-surge buckling of ASTs even though it has been identified as a common mode of AST failure. For this purpose, finite-element simulations were performed to study the effect of the proposed stiffening ring on the buckling response of ASTs. The critical surge height, i.e., the lowest surge height that causes AST buckling, is evaluated for a wide range of tank geometries, material properties, ring section moduli, and positions of the additional ring. The critical surge heights obtained from these simulations are used to obtain a multiparameter regression equation that can predict the critical surge height. The regression equation is further used to derive the optimal section property and the position for the additional ring as a function of tank geometry and material properties. In order to demonstrate the effect of the additional stiffening ring, the change in the critical surge height due to the installation of the additional ring is evaluated for five case-study tanks. The results show that installation of the additional stiffening ring can significantly increase the critical surge height of tanks. Furthermore, considering uncertainties from level of fill in the tank and geometric imperfections, fragility analysis for one of the case study tanks underscores the reduction in fragility, i.e.,ļ¾ conditional probability of buckling failure given surge level, due to the additional ring.en_US
dc.identifier.citationKameshwar, Sabarethinam and Padgett, Jamie E.. "Stiffening Ring Design for Prevention of Storm-Surge Buckling in Aboveground Storage Tanks." <i>Journal of Structural Engineering,</i> 145, no. 3 (2019) American Society of Civil Engineers: https://doi.org/10.1061/(ASCE)ST.1943-541X.0002275.en_US
dc.identifier.doihttps://doi.org/10.1061/(ASCE)ST.1943-541X.0002275en_US
dc.identifier.urihttps://hdl.handle.net/1911/106275en_US
dc.language.isoengen_US
dc.publisherAmerican Society of Civil Engineersen_US
dc.rightsThis is an author's peer-reviewed final manuscript, as accepted by the publisher. The published article is copyrighted by the American Society of Civil Engineers.en_US
dc.titleStiffening Ring Design for Prevention of Storm-Surge Buckling in Aboveground Storage Tanksen_US
dc.typeJournal articleen_US
dc.type.dcmiTexten_US
dc.type.publicationpost-printen_US
Files
Original bundle
Now showing 1 - 5 of 7
Loading...
Thumbnail Image
Name:
Accepted_manuscript.pdf
Size:
498.31 KB
Format:
Adobe Portable Document Format
Description:
Article
Loading...
Thumbnail Image
Name:
Fig1.pdf
Size:
121.89 KB
Format:
Adobe Portable Document Format
Description:
Figure 1
Loading...
Thumbnail Image
Name:
Fig2.pdf
Size:
180.22 KB
Format:
Adobe Portable Document Format
Description:
Figure 2
Loading...
Thumbnail Image
Name:
Fig3.pdf
Size:
159.33 KB
Format:
Adobe Portable Document Format
Description:
Figure 3
Loading...
Thumbnail Image
Name:
Fig4.pdf
Size:
185.48 KB
Format:
Adobe Portable Document Format
Description:
Figure 4