Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging

dc.contributor.advisorClark, John W., Jr.en_US
dc.creatorChang, Guopingen_US
dc.date.accessioned2011-07-25T02:06:35Zen_US
dc.date.available2011-07-25T02:06:35Zen_US
dc.date.issued2010en_US
dc.description.abstractThe aim of this thesis is to design, implement, and evaluate respiratory motion correction techniques that can overcome respiratory motion artifacts in PET/CT imaging. The thesis is composed of three main sections. The first section introduces a novel approach (free-breathing amplitude gating (FBAG) technique) to correct for respiratory motion artifacts. This approach is based on sorting the acquired PET data in multiple amplitude bins which is currently not possible on any commercial PET/CT scanner. The second section is focused on the hardware/software design of an in-house respiratory gating device that is necessary to facilitate the implementation of the FBAG technique. Currently there are no commercially available respiratory gating systems that can generate the necessary triggers required for the FBAG technique. The third section is focused on developing a joint correction technique that can simultaneously suppress respiratory motion artifacts as well as partial volume effects (PVE) which represent another source of image degradation in PET/CT imaging. Computer simulations, phantom studies, as well as patient studies are conducted to test the performance of these proposed techniques and their results are shown in this thesis.en_US
dc.format.mimetypeapplication/pdfen_US
dc.identifier.callnoTHESIS E.E. 2010 CHANGen_US
dc.identifier.citationChang, Guoping. "Respiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imaging." (2010) Diss., Rice University. <a href="https://hdl.handle.net/1911/62125">https://hdl.handle.net/1911/62125</a>.en_US
dc.identifier.urihttps://hdl.handle.net/1911/62125en_US
dc.language.isoengen_US
dc.rightsCopyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.en_US
dc.subjectBiomedical engineeringen_US
dc.subjectElectronicsen_US
dc.subjectElectrical engineeringen_US
dc.subjectNuclear physicsen_US
dc.titleRespiratory motion correction techniques in positron emission tomography/computed tomography (PET/CT) imagingen_US
dc.typeThesisen_US
dc.type.materialTexten_US
thesis.degree.departmentElectrical Engineeringen_US
thesis.degree.disciplineEngineeringen_US
thesis.degree.grantorRice Universityen_US
thesis.degree.levelDoctoralen_US
thesis.degree.nameDoctor of Philosophyen_US