RiceWrist Robotic Device for Upper Limb Training: Feasibility Study and Case Report of Two Tetraplegic Persons with Spinal Cord Injury

dc.citation.firstpage27
dc.citation.issueNumber4
dc.citation.journalTitleInternational Journal of Biological Engineering
dc.citation.lastpage38
dc.citation.volumeNumber2
dc.contributor.authorKadivar, Z.
dc.contributor.authorSullivan, J.L.
dc.contributor.authorEng, D.P.
dc.contributor.authorPehlivan, A.U.
dc.contributor.authorO'Malley, M.K.
dc.contributor.authorYozbatiran, N.
dc.contributor.authorBerliner, J.DO.
dc.contributor.authorBoake, C.
dc.contributor.authorFrancisco, G.E.
dc.date.accessioned2013-07-10T20:29:20Z
dc.date.available2013-07-10T20:29:20Z
dc.date.issued2012
dc.description.abstractRegaining upper extremity function is the primary concern of persons with tetraplegia caused by spinal cord injury (SCI). Robotic rehabilitation has been inadequately tested and underutilized in rehabilitation of the upper extremity in the SCI population. Given the acceptance of robotic training in stroke rehabilitation and SCI gait training, coupled with recent evidence that the spinal cord, like the brain, demonstrates plasticity that can be enhanced by repetitive movement training such as that available with robotic devices, it is probable that robotic upper extremity training of persons with SCI could be clinically beneficial. The primary goal of this pilot study was to test the feasibility of using a novel robotic device –the RiceWrist Exoskeleton- for rehabilitation of the upper limbs (UL) of two tetraplegic persons with incomplete SCI. Two pilot experiments were conducted. Experiment 1was the first novel attempt to administer treatment with the RiceWrist. The left UL of a tetraplegic subject was treated during seven therapy sessions. The subject’s feedback and the investigator’s obser-vations were used to enhance the robotic device and the corresponding graphical-interface. In Experiment 2, a second tetra-plegic subject underwent 10 three-hour training sessions administered by a physical therapist. Smoothness factor (FS) –a new measure developed in Experiment 1- was used as the primary outcome to test the subject’s performance before and after the training. The RiceWrist was modified according to the feedback obtained in Experiment 1. Thereafter, the device was suc-cessfully administered for upper limb training of the tetraplegic individual. Noticeable improvements in FS were observed for the stronger arm of the subject who completed 10 sessions of training. Improvements were also observed in the subject’s hand according to the Jebsen-Taylor Hand Function Test. Results from this study suggest a potential application of the RiceWrist for rehabilitation of SCI individuals and offer valuable information regarding development of UL robotic devices for this population.
dc.embargo.termsnone
dc.identifier.citationKadivar, Z., Sullivan, J.L., Eng, D.P., et al.. "RiceWrist Robotic Device for Upper Limb Training: Feasibility Study and Case Report of Two Tetraplegic Persons with Spinal Cord Injury." <i>International Journal of Biological Engineering,</i> 2, no. 4 (2012) Scientific & Academic Publishing: 27-38. http://dx.doi.org/10.5923/j.ijbe.20120204.01.
dc.identifier.doihttp://dx.doi.org/10.5923/j.ijbe.20120204.01
dc.identifier.urihttps://hdl.handle.net/1911/71522
dc.language.isoeng
dc.publisherScientific & Academic Publishing
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
dc.subject.keywordrobotic devices
dc.subject.keywordRiceWrist
dc.subject.keywordupper extremity
dc.subject.keywordspinal cord injury
dc.titleRiceWrist Robotic Device for Upper Limb Training: Feasibility Study and Case Report of Two Tetraplegic Persons with Spinal Cord Injury
dc.typeJournal article
dc.type.dcmiText
dc.type.publicationpublisher version
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RiceWristRoboticDevice.pdf
Size:
1.82 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description: