Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass gas cell
dc.citation.firstpage | 19821 | en_US |
dc.citation.issueNumber | 15 | en_US |
dc.citation.journalTitle | Optics Express | en_US |
dc.citation.lastpage | 19830 | en_US |
dc.citation.volumeNumber | 23 | en_US |
dc.contributor.author | Dong, Lei | en_US |
dc.contributor.author | Yu, Yajun | en_US |
dc.contributor.author | Li, Chunguang | en_US |
dc.contributor.author | So, Stephen | en_US |
dc.contributor.author | Tittel, Frank K. | en_US |
dc.date.accessioned | 2015-10-30T15:40:40Z | en_US |
dc.date.available | 2015-10-30T15:40:40Z | en_US |
dc.date.issued | 2015 | en_US |
dc.description.abstract | A ppb-level formaldehyde (H2CO) sensor was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) room temperature interband cascade laser (ICL) emitting at 3.59 μm and a miniature dense pattern multipass gas cell with >50 m optical path length. Performance of the sensor was investigated with two measurement schemes: direct absorption (DAS) and wavelength modulation spectroscopy (WMS). With an integration time of less than 1.5 second, a detection limit of ~3 ppbv for H2CO measurement with precision of 1.25 ppbv for DAS and 0.58 ppbv for WMS, respectively, was achieved without zero air based background subtraction. An Allan-Werle variance analysis indicated that the precisions can be further improved to 0.26 ppbv @ 300s for DAS and 69 pptv @ 90 s for WMS, respectively. A side-by-side comparison between two measurement schemes is also discussed in detail. | en_US |
dc.identifier.citation | Dong, Lei, Yu, Yajun, Li, Chunguang, et al.. "Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass gas cell." <i>Optics Express,</i> 23, no. 15 (2015) The Optical Society: 19821-19830. http://dx.doi.org/10.1364/OE.23.019821. | en_US |
dc.identifier.doi | http://dx.doi.org/10.1364/OE.23.019821 | en_US |
dc.identifier.uri | https://hdl.handle.net/1911/82000 | en_US |
dc.language.iso | eng | en_US |
dc.publisher | The Optical Society | en_US |
dc.rights | Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. | en_US |
dc.title | Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass gas cell | en_US |
dc.type | Journal article | en_US |
dc.type.dcmi | Text | en_US |
dc.type.publication | publisher version | en_US |