Double-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)

dc.citation.firstpage12081en_US
dc.citation.issueNumber9en_US
dc.citation.journalTitleOptics Expressen_US
dc.citation.lastpage12091en_US
dc.citation.volumeNumber26en_US
dc.contributor.authorDong, Mingen_US
dc.contributor.authorZheng, Chuantaoen_US
dc.contributor.authorYao, Danen_US
dc.contributor.authorZhong, Guoqiangen_US
dc.contributor.authorMiao, Shuzhuoen_US
dc.contributor.authorYe, Weilinen_US
dc.contributor.authorWang, Yidingen_US
dc.contributor.authorTittel, Frank K.en_US
dc.date.accessioned2018-08-21T16:18:47Zen_US
dc.date.available2018-08-21T16:18:47Zen_US
dc.date.issued2018en_US
dc.description.abstractDesign and fabrication of a dual spot-ring Herriott cell (DSR-HC) were proposed. The sealed Herriott cell with a dimensional size of 5.5 cm × 9.2 cm × 32.1 cm, possessed two input/output coupling holes leading to two absorption path lengths of ~20 m and ~6 m, respectively. An acetylene (C2H2) sensor system with a double-range was developed using the DSR-HC and wavelength modulation spectroscopy (WMS) technique. A near-infrared distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6521.2 cm-1. C2H2concentration measurements were carried out by modulating the laser at a 5 kHz frequency and demodulating the detector signal with LabVIEW software. An Allan-Werle deviation analysis indicated that the limit of detection (LoD) for the two absorption path lengths of 20 m and 6 m are 7.9 parts-per-million in volume (ppmv) and 4.0 ppmv, respectively. The DSR-HC concept can be used to fabricate similar cells for single-gas detection requiring two different detection ranges as well as for dual-gas detection requiring different absorption path lengths.en_US
dc.identifier.citationDong, Ming, Zheng, Chuantao, Yao, Dan, et al.. "Double-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)." <i>Optics Express,</i> 26, no. 9 (2018) Optical Society of America: 12081-12091. https://doi.org/10.1364/OE.26.012081.en_US
dc.identifier.digitaloe-26-9-12081en_US
dc.identifier.doihttps://doi.org/10.1364/OE.26.012081en_US
dc.identifier.urihttps://hdl.handle.net/1911/102487en_US
dc.language.isoengen_US
dc.publisherOptical Society of Americaen_US
dc.rightsAn OSA-formatted open access journal article PDF may be governed by the OSA Open Access Publishing Agreement signed by the author and any applicable copyright laws. Authors and readers may use, reuse, and build upon the article, or use it for text or data mining without asking prior permission from the publisher or the Author(s), as long as the purpose is non-commercial and appropriate attribution is maintained.en_US
dc.rights.urihttps://www.osapublishing.org/library/license_v1.cfm#VOR-OAen_US
dc.titleDouble-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)en_US
dc.typeJournal articleen_US
dc.type.dcmiTexten_US
dc.type.publicationpublisher versionen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
oe-26-9-12081.pdf
Size:
2.91 MB
Format:
Adobe Portable Document Format