Double-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)

dc.citation.firstpage12081
dc.citation.issueNumber9
dc.citation.journalTitleOptics Express
dc.citation.lastpage12091
dc.citation.volumeNumber26
dc.contributor.authorDong, Ming
dc.contributor.authorZheng, Chuantao
dc.contributor.authorYao, Dan
dc.contributor.authorZhong, Guoqiang
dc.contributor.authorMiao, Shuzhuo
dc.contributor.authorYe, Weilin
dc.contributor.authorWang, Yiding
dc.contributor.authorTittel, Frank K.
dc.date.accessioned2018-08-21T16:18:47Z
dc.date.available2018-08-21T16:18:47Z
dc.date.issued2018
dc.description.abstractDesign and fabrication of a dual spot-ring Herriott cell (DSR-HC) were proposed. The sealed Herriott cell with a dimensional size of 5.5 cm × 9.2 cm × 32.1 cm, possessed two input/output coupling holes leading to two absorption path lengths of ~20 m and ~6 m, respectively. An acetylene (C2H2) sensor system with a double-range was developed using the DSR-HC and wavelength modulation spectroscopy (WMS) technique. A near-infrared distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6521.2 cm-1. C2H2concentration measurements were carried out by modulating the laser at a 5 kHz frequency and demodulating the detector signal with LabVIEW software. An Allan-Werle deviation analysis indicated that the limit of detection (LoD) for the two absorption path lengths of 20 m and 6 m are 7.9 parts-per-million in volume (ppmv) and 4.0 ppmv, respectively. The DSR-HC concept can be used to fabricate similar cells for single-gas detection requiring two different detection ranges as well as for dual-gas detection requiring different absorption path lengths.
dc.identifier.citationDong, Ming, Zheng, Chuantao, Yao, Dan, et al.. "Double-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)." <i>Optics Express,</i> 26, no. 9 (2018) Optical Society of America: 12081-12091. https://doi.org/10.1364/OE.26.012081.
dc.identifier.digitaloe-26-9-12081
dc.identifier.doihttps://doi.org/10.1364/OE.26.012081
dc.identifier.urihttps://hdl.handle.net/1911/102487
dc.language.isoeng
dc.publisherOptical Society of America
dc.rightsAn OSA-formatted open access journal article PDF may be governed by the OSA Open Access Publishing Agreement signed by the author and any applicable copyright laws. Authors and readers may use, reuse, and build upon the article, or use it for text or data mining without asking prior permission from the publisher or the Author(s), as long as the purpose is non-commercial and appropriate attribution is maintained.
dc.rights.urihttps://www.osapublishing.org/library/license_v1.cfm#VOR-OA
dc.titleDouble-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)
dc.typeJournal article
dc.type.dcmiText
dc.type.publicationpublisher version
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
oe-26-9-12081.pdf
Size:
2.91 MB
Format:
Adobe Portable Document Format