Absolute calibration of a retarding-potential Mott polarimeter

dc.contributor.advisorDunning, F. B.en_US
dc.creatorOro, David Michaelen_US
dc.date.accessioned2009-06-03T23:57:30Zen_US
dc.date.available2009-06-03T23:57:30Zen_US
dc.date.issued1992en_US
dc.description.abstractMott polarimeters are used in many areas of physics to determine the spin polarization of electrons in studies of processes dependent on the electron's intrinsic spin angular momentum and associated spin magnetic moment. Mott polarimeters work by measuring the left-right asymmetry in the spatial distribution of electrons scattered from high-Z nuclei. The polarization of the incident electrons is related to the measured asymmetry via a parameter known as the effective asymmetry (Sherman) function, S$\sb{\rm eff}$, which must be determined through calibration. This work describes a novel technique for calibrating a Mott polarimeter that makes use of electrons of accurately known polarization obtained through Penning ionization reactions involving electron spin polarized He(2$\sp3$S) metastable atoms. This technique has been used to calibrate a compact retarding-potential Mott polarimeter, and the values of S$\sb{\rm eff}$ are presented for both gold and thorium target foils under a variety of operating conditions.en_US
dc.format.extent49 p.en_US
dc.format.mimetypeapplication/pdfen_US
dc.identifier.callnoThesis Sp. Sci. 1992 Oroen_US
dc.identifier.citationOro, David Michael. "Absolute calibration of a retarding-potential Mott polarimeter." (1992) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/13682">https://hdl.handle.net/1911/13682</a>.en_US
dc.identifier.urihttps://hdl.handle.net/1911/13682en_US
dc.language.isoengen_US
dc.rightsCopyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.en_US
dc.subjectCondensed matter physicsen_US
dc.subjectAtomic physicsen_US
dc.titleAbsolute calibration of a retarding-potential Mott polarimeteren_US
dc.typeThesisen_US
dc.type.materialTexten_US
thesis.degree.departmentSpace Scienceen_US
thesis.degree.disciplineNatural Sciencesen_US
thesis.degree.grantorRice Universityen_US
thesis.degree.levelMastersen_US
thesis.degree.nameMaster of Scienceen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1349028.PDF
Size:
1.55 MB
Format:
Adobe Portable Document Format