Calibration of the E683 main calorimeter (electromagnetic hadronic calorimeter)

Date
1993
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract

The calibration of an electromagnetic-hadronic calorimeter is discussed in the larger context of the physics goals of the experiment in which it was used. Descriptions of the experimental apparatus are given. The methods employed for balancing electromagnetic response are discussed, including cuts on data integrity and fiducial cuts on energy distributions, and the reliability of the balancing algorithm. Results for energy resolution are given and are found to be in reasonable agreement with expectation. Extension of these balancing methods to hadronic response is discussed along with preliminary results. The ratio of hadronic to electromagnetic response is considered and is found to be in reasonable agreement with expectation. Methods of measuring and correcting for the calorimeter's evolution through time are briefly discussed.

Description
Degree
Master of Science
Type
Thesis
Keywords
Particle physics, Elementary particles, High energy physics
Citation

Morrow, Gregory P.. "Calibration of the E683 main calorimeter (electromagnetic hadronic calorimeter)." (1993) Master’s Thesis, Rice University. https://hdl.handle.net/1911/13765.