Microprocessor control of a combined assist system for the profound support of the failing heart

dc.contributor.advisorClark, John W.en_US
dc.contributor.committeeMemberWalker, William F.en_US
dc.contributor.committeeMemberParks, Thomas W.en_US
dc.creatorPhilippe, Edouard A.en_US
dc.date.accessioned2018-12-18T21:19:20Zen_US
dc.date.available2018-12-18T21:19:20Zen_US
dc.date.issued1979en_US
dc.description.abstractConventional non-invasive mechanical circulatory assist methods such as intra-aortic balloon pumping are of little effectiveness in cases of severe ventricular failure. The proposed study is concerned with the development and testing, on a mock circulatory loop and in a series of dog experiments, of an automated combined assist system for the profound support of the failing heart. This system is mildly invasive and consists of the synergistic use of intra-aortic balloon pumping and partial veno-arterial bypass. Previous in vivo studies using this system with no automation have shown that it is quite effective in achieving its clinical objectives, and our purpose is to investigate the ability of the control systems developed herein to match the optimal manual setting of the assist system. The end result of the project is a portable compact automatically controlled ventricular assist system that can be rapidly and easily instituted, thus improving the chance of survival and recovery of acute myocardial infarction and cardiogenic shock victims.en_US
dc.format.digitalOriginreformatted digitalen_US
dc.format.extent134 ppen_US
dc.identifier.callnoTHESIS E.E. 1979 PHILIPPEen_US
dc.identifier.citationPhilippe, Edouard A.. "Microprocessor control of a combined assist system for the profound support of the failing heart." (1979) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/104235">https://hdl.handle.net/1911/104235</a>.en_US
dc.identifier.digitalRICE1864en_US
dc.identifier.urihttps://hdl.handle.net/1911/104235en_US
dc.language.isoengen_US
dc.rightsCopyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.en_US
dc.titleMicroprocessor control of a combined assist system for the profound support of the failing hearten_US
dc.typeThesisen_US
dc.type.materialTexten_US
thesis.degree.departmentElectrical Engineeringen_US
thesis.degree.disciplineEngineeringen_US
thesis.degree.grantorRice Universityen_US
thesis.degree.levelMastersen_US
thesis.degree.nameMaster of Scienceen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RICE1864.pdf
Size:
5.35 MB
Format:
Adobe Portable Document Format