QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL

dc.citation.issueNumber1en_US
dc.citation.journalTitleOptics Expressen_US
dc.citation.volumeNumber21en_US
dc.contributor.authorMa, Yufei
dc.contributor.authorLewicki, Rafał
dc.contributor.authorRazeghi, Manijeh
dc.contributor.authorTittel, Frank K.
dc.date.accessioned2013-09-18T17:03:39Z
dc.date.available2013-09-18T17:03:39Z
dc.date.issued2013-01-14
dc.description.abstractAn ultra-sensitive and selective quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor platform was demonstrated for detection of carbon monoxide (CO) and nitrous oxide (N2O). This sensor used a stateof- the art 4.61 μm high power, continuous wave (CW), distributed feedback quantum cascade laser (DFB-QCL) operating at 10°C as the excitation source. For the R(6) CO absorption line, located at 2169.2 cm−1, a minimum detection limit (MDL) of 1.5 parts per billion by volume (ppbv) at atmospheric pressure was achieved with a 1 sec acquisition time and the addition of 2.6% water vapor concentration in the analyzed gas mixture. For the N2O detection, a MDL of 23 ppbv was obtained at an optimum gas pressure of 100 Torr and with the same water vapor content of 2.6%. In both cases the presence of water vapor increases the detected CO and N2O QEPAS signal levels as a result of enhancing the vibrational-translational relaxation rate of both target gases. Allan deviation analyses were performed to investigate the long term performance of the CO and N2O QEPAS sensor systems. For the optimum data acquisition time of 500 sec a MDL of 340 pptv and 4 ppbv was obtained for CO and N2O detection, respectively. To demonstrate reliable and robust operation of the QEPAS sensor a continuous monitoring of atmospheric CO and N2O concentration levels for a period of 5 hours were performed.en_US
dc.identifier.citationY. Ma, R. Lewicki, M. Razeghi and F. K. Tittel, "QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL," <i>Optics Express,</i> vol. 21, no. 1, 2013.*
dc.identifier.doihttp://dx.doi.org/10.1364/OE.21.001008en_US
dc.identifier.urihttps://hdl.handle.net/1911/72091
dc.language.isoengen
dc.publisherOptical Society of Americaen_US
dc.titleQEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCLen_US
dc.typeJournal articleen_US
dc.type.dcmiTexten
dc.type.dcmiTexten_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
QEPAS.pdf
Size:
1.81 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections