A Phantom Study of In-beam PET Imaging for Proton Beam Range Verification

dc.contributor.advisorClark, John W., Jr.
dc.contributor.committeeMemberKelly, Kevin F.
dc.contributor.committeeMemberJacot, Jeffrey G.
dc.contributor.committeeMemberShao, Yiping
dc.creatorLou, Kai
dc.date.accessioned2014-09-16T20:40:22Z
dc.date.available2014-09-16T20:40:22Z
dc.date.created2014-05
dc.date.issued2013-12-17
dc.date.submittedMay 2014
dc.date.updated2014-09-16T20:40:23Z
dc.description.abstractIn-beam PET imaging is an advanced image-based method to verify the proton beam range for proton therapy by measuring proton-induced positron activity distribution and activity range. This study investigates the feasibility, accuracy and precision of the activity range measurement with a high-performance compact PET prototype system for in-beam PET imaging. An experiment with a homogeneous PMMA phantom and several Monte Carlo simulation studies are conducted. The results have shown that the prototype PET can provide reasonably good images for the activity range measurement even with low count statistics; the accuracy of activity range measurement reaches sub-millimeter; 11C is the most dominating positron emission isotope contributing to the overall positron activity; the image quality and the precision of activity range measurement depend on the count statistics, and high count statistics leads to improved image quality and precision. Although the study is preliminary with simple system set-ups, it does provide interesting and important results which should lay the basis leading to future clinically relevant investigations.
dc.format.mimetypeapplication/pdf
dc.identifier.citationLou, Kai. "A Phantom Study of In-beam PET Imaging for Proton Beam Range Verification." (2013) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/77203">https://hdl.handle.net/1911/77203</a>.
dc.identifier.urihttps://hdl.handle.net/1911/77203
dc.language.isoeng
dc.rightsCopyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
dc.subjectProton therapy
dc.subjectProton beam range verification
dc.subjectPET
dc.subjectElectrical engineering
dc.subjectComputer engineering
dc.titleA Phantom Study of In-beam PET Imaging for Proton Beam Range Verification
dc.typeThesis
dc.type.materialText
thesis.degree.departmentApplied Physics
thesis.degree.disciplineNatural Sciences
thesis.degree.grantorRice University
thesis.degree.levelMasters
thesis.degree.nameMaster of Science
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MasterThesis_KaiLou.pdf
Size:
4.44 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
931 B
Format:
Plain Text
Description: