dc.description.abstractThe inter-beat-interval (time period of the cardiac cycle) changes slightly for every heartbeat; this variation is measured as Heart Rate Variability (HRV). HRV is presumed to occur due to interactions between the parasympathetic and sympathetic nervous system. Therefore, it is sometimes used as an indicator of the stress level of an individual. HRV also reveals some clinical information about cardiac health. Currently, HRV is accurately measured using contact devices such as a pulse oximeter. However, recent research in the eld of non-contact imaging Photoplethysmography (IPPG) has made it possible to extract vital sign measurements from the video recording of any exposed skin surface, such as a person's face. Extracting HRV using a camera holds a lot of promise as it opens up the applications of stress, engagement monitoring during interviews and online education. It can also be used as a non-invasive monitoring solution for measuring autonomous nervous system function for diabetic patients who are at high risk for developing diabetic autonomic neuropathy. The current signal processing methods for extracting HRV using peak detection perform well for contact-based systems but have poor performance for the IPPG signals. The main reason for this poor performance is the fact that current methods are sensitive to large noise sources which are often present in IPPG data. Further, current methods are not robust to motion artifacts that are common in IPPG systems. We developed a new algorithm, HRVCam, for robustly extracting HRV even in low SNR such as is common with IPPG recordings. HRVCam combines spatial combination and frequency demodulation to obtain HRV from the instantaneous frequency of the IPPG signal. HRVCam outperforms other current methods of HRV estimation. Ground truth data was obtained from FDA-approved pulse oximeter for validation purposes. HRVCam improves the accuracy by 25% for light skin tones and by 60% for darker skin tones. HRVCam also allows us to measure HRV during high motion scenarios such as talking with an error of 25%. In such scenarios state-of-the-art approaches perform rather poorly.en_US
dc.embargo.terms2019-06-01en_US
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationPai, Amruta. "HRVCam: Measuring Heart Rate Variability With A Camera." (2018) Master’s Thesis, Rice University. <a href="https://hdl.handle.net/1911/105898">https://hdl.handle.net/1911/105898</a>.en_US
dc.identifier.urihttps://hdl.handle.net/1911/105898en_US
dc.language.isoengen_US
dc.rightsCopyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.en_US
dc.subjectHeart Rate Variabilityen_US
dc.subjectImaging Photoplethysmographyen_US
dc.subjectCameraen_US
dc.titleHRVCam: Measuring Heart Rate Variability With A Cameraen_US
dc.typeThesisen_US
dc.type.materialTexten_US
thesis.degree.departmentElectrical and Computer Engineeringen_US
thesis.degree.disciplineEngineeringen_US
thesis.degree.grantorRice Universityen_US
thesis.degree.levelMastersen_US
thesis.degree.nameMaster of Scienceen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PAI-DOCUMENT-2018.pdf
Size:
10.08 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
PROQUEST_LICENSE.txt
Size:
5.84 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
LICENSE.txt
Size:
2.6 KB
Format:
Plain Text
Description: