Browsing by Author "Wu, Hongpeng"
Now showing 1 - 17 of 17
Results Per Page
Sort Options
Item Acoustic Detection Module Design of a Quartz-Enhanced Photoacoustic Sensor(MDPI, 2019) Wei, Tingting; Wu, Hongpeng; Dong, Lei; Tittel, Frank K.This review aims to discuss the latest advancements of an acoustic detection module (ADM) based on quartz-enhanced photoacoustic spectroscopy (QEPAS). Starting from guidelines for the design of an ADM, the ADM design philosophy is described. This is followed by a review of the earliest standard quartz tuning fork (QTF)-based ADM for laboratory applications. Subsequently, the design of industrial fiber-coupled and free-space ADMs based on a standard QTF for near-infrared and mid-infrared laser sources respectively are described. Furthermore, an overview of the latest development of a QEPAS ADM employing a custom QTF is reported. Numerous application examples of four QEPAS ADMs are described in order to demonstrate their reliability and robustness.Item Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring(Springer Nature, 2017) Wu, Hongpeng; Dong, Lei; Zheng, Huadan; Yu, Yajun; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a sensitive gas detection technique which requires frequent calibration and has a long response time. Here we report beat frequency (BF) QEPAS that can be used for ultra-sensitive calibration-free trace-gas detection and fast spectral scan applications. The resonance frequency and Q-factor of the quartz tuning fork (QTF) as well as the trace-gas concentration can be obtained simultaneously by detecting the beat frequency signal generated when the transient response signal of the QTF is demodulated at its non-resonance frequency. Hence, BF-QEPAS avoids a calibration process and permits continuous monitoring of a targeted trace gas. Three semiconductor lasers were selected as the excitation source to verify the performance of the BF-QEPAS technique. The BF-QEPAS method is capable of measuring lower trace-gas concentration levels with shorter averaging times as compared to conventional PAS and QEPAS techniques and determines the electrical QTF parameters precisely.Item Cavity-enhanced photoacoustic sensor based on a whispering-gallery-mode diode laser(Copernicus Publications, 2019) Pan, Yufeng; Dong, Lei; Wu, Hongpeng; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.A cavity-enhanced photoacoustic (CEPA) sensor was developed based on an ultra-narrow linewidth whispering-gallery-mode (WGM) diode laser. A cavity-enhanced photoacoustic module (CEPAM) was designed to match the output beam from the WGM-diode laser, resulting in an increase in the excitation light power, which, in turn, significantly enhanced the photoacoustic signal amplitude. The results show that a signal gain factor of 166 was achieved, which is in excellent agreement with the power enhancement factor of 175 after considering the power transmissivity. The performance of the sensor was evaluated in terms of the detection sensitivity and linearity. A 1σ detection limit of 0.45 ppmV for C2H2 detection was obtained at atmospheric pressure with a 1 s averaging time.Item Compact photoacoustic module for methane detection incorporating interband cascade light emitting device(The Optical Society, 2017) Zheng, Huadan; Lou, Minhan; Dong, Lei; Wu, Hongpeng; Ye, Weilin; Yin, Xukun; Kim, Chul Soo; Kim, Mijin; Bewley, William W.; Merritt, Charles D.; Canedy, Chadwick L.; Warren, Michael V.; Vurgaftman, Igor; Meyer, Jerry R.; Tittel, Frank K.A photoacoustic module (PAM) for methane detection was developed by combining a novel 3.2 μm interband cascade light emitting device (ICLED) with a compact differential photoacoustic cell. The ICLED with a 22-stage interband cascade active core emitted a collimated power of ~700 μW. A concave Al-coat reflector was positioned adjacent to the photoacoustic cell to enhance the gas absorption length. Assembly of the ICLED and reflector with the photoacoustic cell resulted in a robust and portable PAM without any moving parts. The PAM performance was evaluated in terms of operating pressure, sensitivity and linearity. A 1σ detection limit of 3.6 ppmv was achieved with a 1-s integration time.Item Compact QEPAS humidity sensor in SF6 buffer gas for high-voltage gas power systems(Elsevier, 2022) Yin, Xukun; Dong, Lei; Wu, Hongpeng; Gao, Miao; Zhang, Le; Zhang, Xueshi; Liu, Lixian; Shao, Xiaopeng; Tittel, Frank K.In SF6 insulated high-voltage gas power systems, H2O is the most problematic impurity which not only decreases insulation performance but also creates an acidic atmosphere that promotes corrosion. Corrosion damages electrical equipment and leads to leaks, which pose serious safety hazards to people and the environment. A QEPAS-based sensor system for the sub-ppm level H2O detection in SF6 buffer gas was developed by use of a near-infrared commercial DFB diode laser. Since the specific physical constants of SF6 are strongly different from that of N2 or air, the resonant frequency and Q-factor of the bare quartz tuning fork (QTF) had changed to 32,763 Hz and 4173, respectively. The optimal vertical detection position was 1.2 mm far from the QTF opening. After the experimental optimization of acoustic micro-resonator (AmR) parameters, gas pressures, and modulation depths, a detection limit of 0.49 ppm was achieved for an averaging time of 1 s, which provided a powerful prevention tool for the safety monitoring in power systems.Item Compact TDLAS based sensor design using interband cascade lasers for mid-IR trace gas sensing(The Optical Society, 2016) Dong, Lei; Tittel, Frank K.; Li, Chunguang; Sanchez, Nancy P.; Wu, Hongpeng; Zheng, Chuantao; Yu, Yajun; Sampaolo, Angelo; Griffin, Robert J.Two compact TDLAS sensor systems based on different structural optical cores were developed. The two optical cores combine two recent developments, gallium antimonide (GaSb)-based ICL and a compact multipass gas cell (MPGC) with the goal to create compact TDLAS based sensors for the mid-IR gas detection with high detection sensitivity and low power consumption. The sensors achieved minimum detection limits of ~5 ppbv and ~8 ppbv, respectively, for CH4 and C2H6 concentration measurements with a 3.7-W power consumption.Item CW DFB-QCL and EC-QCL based sensor for simultaneous NO and NO2 measurements via frequency modulation multiplexing using multi-pass absorption spectroscopy(SPIE, 2017) Yu, Yajun; Sanchez, Nancy P.; Lou, Minhan; Zheng, Chuantao; Wu, Hongpeng; Głuszek, Aleksander K.; Hudzikowski, Arkadiusz J.; Griffin, Robert J.; Tittel, Frank K.Nitrogen oxides (NOx), including nitric oxide (NO) and nitrogen dioxide (NO2) play important roles in determining the photochemistry of the ambient atmosphere, controlling the production of tropospheric ozone, affecting the concentration levels of the hydroxyl radical, and forming acid precipitation. A sensor system capable of simultaneous measurements of NO and NO2 by using a commercial 76 m astigmatic multi-pass gas cell (MPGC) was developed in order to enable fast-response NOx detection. A continuous wave (CW), distributed-feedback (DFB) quantum cascade laser (QCL) and a CW external-cavity (EC) QCL were employed for targeting a NO absorption doublet at 1900.075 cm-1 and a NO2 absorption line at 1630.33 cm-1, respectively. Both laser beams were combined and transmitted through the MPGC in an identical optical path and subsequently detected by a single mid-infrared detector. A frequency modulation multiplexing scheme was implemented by modulating the DFB-QCL and EC-QCL at different frequencies and demodulating the detector signal with two Labview software based lock-in amplifiers to extract the corresponding second-harmonic (2f) components. Continuous monitoring of NO and NO2 concentration levels was achieved by locking the laser frequencies to the selected absorption lines utilizing a reference cell filled with high concentrations of NO and NO2. The experimental results indicate minor performance degradation associated with frequency modulation multiplexing and no cross talk between the two multiplexed detection channels. The performance of the reported sensor system was evaluated for real time, sensitive and precise detection of NO and NO2 simultaneously.Item Highly sensitive and selective CO sensor using a 2.33 μm diode laser and wavelength modulation spectroscopy(Optical Society of America, 2018) Cui, Ruyue; Dong, Lei; Wu, Hongpeng; Li, Shangzhi; Zhang, Lei; Ma, Weiguang; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.A ppm-level CO sensor based on a 2f wavelength modulation spectroscopy (2f-WMS) technique was developed for the application of SF6 decomposition analysis in an electric power system. A detailed investigation of the optimum target line selection was carried out to avoid spectral interference from high purity SF6 in a wide wavelength range. A diode laser emitting at 2.33 μm and a 14.5-m multipass gas cell (MGC) was employed to target the R(6) line of the CO first overtone band and increase the optical path, respectively, thus resulting in a minimum detection sensitivity of 1 ppm. A Levenberg-Marquardt nonlinear least-squares fit algorithm makes full use of the information from all data points of the 2f spectrum and as a result, a measurement precision of ~40 ppb was achieved with a data update rate of 0.6 s. The sensor performance was also evaluated in terms of the gas flow rate, stability, and linearity. The results showed that the best operating condition with a precision of 6 ppb can be achieved by increasing the gas flow rate to the value that matches the optimum averaging time of 48 s.Item Highly sensitive photoacoustic multicomponent gas sensor for SF6 decomposition online monitoring(Optical Society of America, 2019) Yin, Xukun; Dong, Lei; Wu, Hongpeng; Zhang, Lei; Ma, Weiguang; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.A ppb-level photoacoustic multicomponent gas sensor system for sulfur hexafluoride (SF6) decomposition detection was developed by the use of two near-infrared (NIR) diode lasers and an ultraviolet (UV) solid-state laser. A telecommunication fiber amplifier module was used to boost up the excitation optical power from the two NIR lasers. A dual-channel high-Q photoacoustic cell (PAC) was designed for the simultaneous detection of CO, H2S, and SO2 in SF6 buffer gas by means of a time division multiplexing (TDM) method. Feasibility and performance of the multicomponent sensor was evaluated, resulting in minimum detection limits of 435 ppbv, 89 ppbv, and 115 ppbv for CO, H2S, and SO2 detection at atmospheric pressure.Item Highly sensitive SO2 photoacoustic sensor for SF6decomposition detection using a compact mW-level diode-pumped solid-state laser emitting at 303 nm(The Optical Society, 2017) Yin, Xukun; Dong, Lei; Wu, Hongpeng; Zheng, Huadan; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.A compact ppb-level SO2 photoacoustic sensor was developed for the application of SF6decomposition detection in electric power systems. The selection of the SO2 target spectrum is discussed in detail in the infrared (IR) and ultraviolet (UV) spectral regions. Based on the result of the spectrum selection, a small-sized UV-band diode-pumped solid-state laser (DPSSL) emitting at 303.6 nm with an output power of 5 mW was developed. A differential photoacoustic cell (PAC) was designed to match the output optical beam, obtain a high Q-factor and reduce the system flow noise in the SF6 buffer gas. The performance of the sensor system was assessed in terms of gas flow rate, linearity and detection sensitivity. A SO2 detection limit (1σ) of 74 ppbv was achieved with a 1-s integration time, which corresponds to a normalized noise equivalent absorption (NNEA) coefficient of 1.15 × 10−9 cm−1WHz-1/2.Item Piezo-enhanced acoustic detection module for mid-infrared trace gas sensing using a grooved quartz tuning fork(Optica Publishing Group, 2019) Li, Shangzhi; Li, Shangzhi; Wu, Hongpeng; Wu, Hongpeng; Cui, Ruyue; Cui, Ruyue; Sampaolo, Angelo; Patimisco, Pietro; Spagnolo, Vincenzo; Spagnolo, Vincenzo; Spagnolo, Vincenzo; Tittel, Frank K.; Dong, Lei; Dong, LeiA grooved quartz tuning fork (QTF) with a prong spacing of 800 µm for QEPAS application is reported. The prongs spacing is large enough to facilitate optical alignments when a degraded laser beam is used for QEPAS-based trace gas sensors. The grooved QTF has a resonance frequency of 15.2 kHz at atmospheric pressure and is characterized by four rectangular grooves carved on the QTF prong surfaces. With a grooved-prong, the electrical resistance R of the QTF is reduced resulting in an enhanced piezoelectric signal, while the Q factor is not affected, remaining as high as 15000 at atmospheric pressure. The geometric parameters of the acoustic micro resonators (AmRs) for on-beam QEPAS were optimized to match the grooved QTF, and a signal-to-noise gain factor of ∼ 30 was obtained with an optimum configuration. The performance of the QEPAS-based sensor was demonstrated exploiting an interband cascade laser (ICL) for CH4 detection and a 1σ normalized noise equivalent absorption (NNEA) coefficient of 4.1×10−9 cm−1 W/√Hz was obtained at atmospheric pressure.Item Ppb-level H2S detection for SF6 decomposition based on a fiber-amplified telecommunication diode laser and a background-gas-induced high-Q photoacoustic cell(AIP Publishing, 2017) Yin, Xukun; Dong, Lei; Wu, Hongpeng; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.A ppb-level hydrogen sulfide (H2S) gas sensor for sulfur hexafluoride (SF6) decomposition analysis was developed by means of a background-gas-induced high-Q differential photoacoustic cell (PAC) and a fiber-amplified telecommunication diode laser. The watt-level excitation laser power compensates the sensitivity loss as a result of using a low cost, near-IR laser source. The differential design with a large cylindrical resonator diameter allows the PAC to accommodate the high power beam and maintain a low noise level output. The theory of background-gas-induced high-Q PAC is provided and was verified experimentally. A H2S detection limit (1σ) of 109 ppb in a SF6 buffer gas was achieved for an averaging time of 1 s, which corresponds to a normalized noise equivalent absorption coefficient of 2.9 × 10−9 cm−1 W Hz−1/2.Item Quartz enhanced photoacoustic H2S gas sensor based on a fiber-amplifier source and a custom tuning fork with large prong spacing(AIP Publishing LLC, 2015) Wu, Hongpeng; Sampaolo, Angelo; Dong, Lei; Patimisco, Pietro; Liu, Xiaoli; Zheng, Huadan; Yin, Xukun; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Spagnolo, Vincenzo; Jia, Suotang; Tittel, Frank K.A quartz enhanced photoacoustic spectroscopy (QEPAS) sensor, employing an erbium-doped fiber amplified laser source and a custom quartz tuning fork (QTF) with its two prongs spaced ∼800 μm apart, is reported. The sensor employs an acoustic micro-resonator (AmR) which is assembled in an “on-beam” QEPAS configuration. Both length and vertical position of the AmR are optimized in terms of signal-to-noise ratio, significantly improving the QEPAS detection sensitivity by a factor of ∼40, compared to the case of a sensor using a bare custom QTF. The fiber-amplifier-enhanced QEPAS sensor is applied to H2S trace gas detection, reaching a sensitivity of ∼890 ppb at 1 s integration time, similar to those obtained with a power-enhanced QEPAS sensor equipped with a standard QTF, but with the advantages of easy optical alignment, simple installation, and long-term stability.Item Quartz-enhanced conductance spectroscopy for nanomechanical analysis of polymer wire(AIP Publishing LLC, 2015) Zheng, Huadan; Yin, Xukun; Zhang, Guofeng; Dong, Lei; Wu, Hongpeng; Liu, Xiaoli; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.Quartz-enhanced conductance spectroscopy is developed as an analytical tool to investigate dynamic nanomechanical behaviors of polymer wires, in order to determine the glass transition temperature (Tg). A polymethyl methacrylate (PMMA) microwire with a diameter of 10 μm was bridged across the prongs of a quartz tuning fork (QTF). With the advantage of QTF self-sensing as compared with micro-cantilevers or other resonators, the resonance frequency and Q factor can be directly determined by means of its electrical conductance spectra with respect to the frequency of the external excitation source (dI/dV vs f), and therefore, no optical beam is required. The Tg of the PMMA microwire was determined by the maximum loss modulus of the QTF, calculated from the resonance frequency and the Q factor as a function of temperature. The measured Tg of the PMMA is 103 °C with an error of ±2 °C. Both heating/cooling and physical aging experiments were carried out, demonstrating that the technique is both reversible and reproducible.Item Quartz-enhanced photoacoustic sensor for ethylene detection implementing optimized custom tuning fork-based spectrophone(Optical Society of America, 2019) Giglio, Marilena; Elefante, Arianna; Patimisco, Pietro; Sampaolo, Angelo; Sgobba, Fabrizio; Rossmadl, Hubert; Mackowiak, Verena; Wu, Hongpeng; Tittel, Frank K.; Dong, Lei; Spagnolo, VincenzoThe design and realization of two highly sensitive and easily interchangeable spectrophones based on custom quartz tuning forks, with a rectangular (S1) or T-shaped (S2) prongs geometry, is reported. The two spectrophones have been implemented in a QEPAS sensor for ethylene detection, employing a DFB-QCL emitting at 10.337 μm with an optical power of 74.2 mW. A comparison between their performances showed a signal-to-noise ratio 3.4 times higher when implementing the S2 spectrophone. For the S2-based sensor, a linear dependence of the QEPAS signal on ethylene concentration was demonstrated in the 5 ppm −100 ppm range. For a 10 s lock-in integration time, an ethylene minimum detection limit of 10 ppb was calculated.Item Simultaneous dual-gas QEPAS detection based on a fundamental and overtone combined vibration of quartz tuning fork(AIP Publishing LLC, 2017) Wu, Hongpeng; Yin, Xukun; Dong, Lei; Pei, Kailong; Sampaolo, Angelo; Patimisco, Pietro; Zheng, Huadan; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Spagnolo, Vincenzo; Jia, Suotang; Tittel, Frank K.A dual-gas quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor system based on a frequency division multiplexing technique of a quartz tuning fork (QTF) was developed and experimentally demonstrated. Two beams from two independently modulated lasers are focused at two different positions between the QTF prongs to excite both the QTF fundamental and 1st overtone flexural modes simultaneously. The 2f-wavelength modulation technique is employed by applying two sinusoidal dithers, whose frequencies are equal to a half of the QTF fundamental and 1st overtone frequencies, respectively, to the currents of two excitation lasers. The resonance frequency difference between two flexural modes ensures that the correlated photoacoustic signals generated by different target gases do not interfere with each other. The proposed QEPAS methodology realizes a continuous real-time dual-gas monitoring with a simple setup and small sensor size compared with previous multi-gas QEPAS sensors.Item Single-tube on beam quartz-enhanced photoacoustic spectrophones exploiting a custom quartz tuning fork operating in the overtone mode(SPIE, 2017) Giglio, Marilena; Sampaolo, Angelo; Patimisco, Pietro; Zheng, Huadan; Wu, Hongpeng; Dong, Lei; Tittel, Frank K.; Spagnolo, VincenzoWe report here on the realization of a single-tube on-beam quartz-enhanced photoacoustic (QEPAS) spectroscopy sensor employing a custom-made quartz tuning fork (QTF) with a large prong spacing. The prongs of the QTF have been designed in order to provide a quality factor twice higher when the QTF operates in the first overtone flexural mode than in the fundamental mode. The influence of the microresonator tube on the main parameters characterizing the sensing performance of the QEPAS spectrophone, including the quality factor, the magnitude of the QEPAS signal and the associated background noise was investigated in detail.