Repository logo
English
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • All of R-3
English
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Samaniego, Adam Patric"

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    mobileVision: A Face-mounted, Voice-activated, Non-mydriatic "Lucky" Ophthalmoscope
    (2014-12-11) Samaniego, Adam Patric; Veeraraghavan, Ashok; Sabharwal, Ashutosh; Zhong, Lin; Woods, Gary
    mobileVision is a portable, robust, smartphone-based ophthalmoscopy system intended to reduce the barriers to ocular pathology screening in developing and underserved regions. Through smartphone integration and ergonomic design, the system demonstrates automatic compensation for patient refractive error, voice-activated multi-shot retinal image acquisition without pupil dilation, and touch-gesture based control of patient fixation and accommodation. Further, a lucky imaging and retinal stitching pipeline is developed and demonstrated, which not only increases overall retinal field-of-view, but also makes the system robust to patient saccades, blinks, device jitter, and imaging artifacts such as noise or unintended scattering from ocular surfaces. The prototype is tested through a combination of mock eye tests and in-vivo trials. The current prototype can image over +/-45 degrees of retina with an estimated 23.5 um of retinal resolution for patients with between -6D to +13D refractive error.