Browsing by Author "Lincoln, Don"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
Item Design and construction of a beam calorimeter for E683 at FNAL(1990) Lincoln, Don; Corcoran, Marjorie D.A steel-scintillator calorimeter has been designed to be used in a 250 GeV photon beam, and consists of approximately 10 nuclear absorption lengths of steel. Its sampling frequency is 1.5" and the sampling medium is 1/4" Kyowa SCSN-61T polystyrene based scintillator. Y7 Kyowa WLS was used to collect light into 8 Hamamatsu R2154 photomultipliers. A monitoring system has been built for the calorimeter. A LSI UV laser pumps a sample of SCSN-61T, which emits light that is subsequently shifted by Y7 and transported to the PM's via jacketted 1 mm acrylic fibers. It simulates the passage of a charged particle. A PIN photodiode also monitors the light output, for cross reference with the PM's. Interspersed among the steel and scintillator, there are 6 PWC's whose purpose is to discriminate between electromagnetic and hadronic showers. Some position information can be gathered. The PWC inter-wire spacing is approximately 1 cm. (Abstract shortened with permission of author.)