Browsing by Author "Hudzikowski, Arkadiusz J."
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item A compact mid-infrared dual-gas CH4/C2H6 sensor using a single interband cascade laser and custom electronics(SPIE, 2017) Ye, Weilin; Zheng, Chuantao; Tittel, Frank K.; Sanchez, Nancy P.; Gluszek, Aleksander K.; Hudzikowski, Arkadiusz J.; Lou, Minhan; Dong, Lei; Griffin, Robert J.A compact mid-infrared (MIR) dual-gas sensor system was demonstrated for simultaneous detection of methane (CH4) and ethane (C2H6) using a single continuous-wave (CW) interband cascade laser (ICL) based on tunable laser absorption spectroscopy (TDLAS) and wavelength modulation spectroscopy (WMS). Ultracompact custom electronics were developed, including a laser current driver, a temperature controller and a lock-in amplifier. These custom electronics reduce the size and weight of the sensor system as compared with a previous version based on commercial electronics. A multipass gas cell with an effective optical length of 54.6 m was employed to enhance the absorption signal. A 3337 nm ICL was capable of targeting a C2H6 absorption line at 2996.88 cm-1 and a CH4 line at 2999.06 cm-1. Dual-gas detection was realized by scanning both the CH4 and C2H6 absorption lines. Based on an Allan deviation analysis, the 1 σ minimum detection limit (MDL) was 17.4 ppbv for CH4 and 2.4 ppbv for C2H6 with an integration time of 4.3 s. TDLAS based sensor measurements for both indoor and outdoor mixing ratios of CH4 and C2H6 were conducted. The reported single ICL based dual-gas sensor system has the advantages of reduced size and cost without influencing the midinfrared sensor detection sensitivity, selectivity and reliability.Item CW DFB-QCL and EC-QCL based sensor for simultaneous NO and NO2 measurements via frequency modulation multiplexing using multi-pass absorption spectroscopy(SPIE, 2017) Yu, Yajun; Sanchez, Nancy P.; Lou, Minhan; Zheng, Chuantao; Wu, Hongpeng; Głuszek, Aleksander K.; Hudzikowski, Arkadiusz J.; Griffin, Robert J.; Tittel, Frank K.Nitrogen oxides (NOx), including nitric oxide (NO) and nitrogen dioxide (NO2) play important roles in determining the photochemistry of the ambient atmosphere, controlling the production of tropospheric ozone, affecting the concentration levels of the hydroxyl radical, and forming acid precipitation. A sensor system capable of simultaneous measurements of NO and NO2 by using a commercial 76 m astigmatic multi-pass gas cell (MPGC) was developed in order to enable fast-response NOx detection. A continuous wave (CW), distributed-feedback (DFB) quantum cascade laser (QCL) and a CW external-cavity (EC) QCL were employed for targeting a NO absorption doublet at 1900.075 cm-1 and a NO2 absorption line at 1630.33 cm-1, respectively. Both laser beams were combined and transmitted through the MPGC in an identical optical path and subsequently detected by a single mid-infrared detector. A frequency modulation multiplexing scheme was implemented by modulating the DFB-QCL and EC-QCL at different frequencies and demodulating the detector signal with two Labview software based lock-in amplifiers to extract the corresponding second-harmonic (2f) components. Continuous monitoring of NO and NO2 concentration levels was achieved by locking the laser frequencies to the selected absorption lines utilizing a reference cell filled with high concentrations of NO and NO2. The experimental results indicate minor performance degradation associated with frequency modulation multiplexing and no cross talk between the two multiplexed detection channels. The performance of the reported sensor system was evaluated for real time, sensitive and precise detection of NO and NO2 simultaneously.Item Mid-infrared dual-gas sensor for simultaneous detection of methane and ethane using a single continuous-wave interband cascade laser(The Optical Society, 2016) Ye, Weilin; Li, Chunguang; Zheng, Chuantao; Sanchez, Nancy P.; Gluszek, Aleksander K.; Hudzikowski, Arkadiusz J.; Dong, Lei; Griffin, Robert J.; Tittel, Frank K.A continuous-wave (CW) interband cascade laser (ICL) based mid-infrared sensor system was demonstrated for simultaneous detection of atmospheric methane (CH4) and ethane (C2H6). A 3.337 µm CW ICL with an emitting wavenumber range of 2996.0−3001.5 cm−1 was used to simultaneously target two absorption lines, C2H6 at 2996.88 cm−1 and CH4 at 2999.06 cm−1, respectively. The sensor performance was first evaluated for single-gas detection by only targeting the absorption line of one gas species. Allan deviations of 11.2 parts per billion in volume (ppbv) for CH4 and 1.86 ppbv for C2H6 with an averaging time of 3.4 s were achieved for the detection of these two gases. Dual-gas detection was realized by using a long-term scan signal to target both CH4 and C2H6 lines. The Allan deviations increased slightly to 17.4 ppbv for CH4 and 2.4 ppbv for C2H6 with an averaging time of 4.6 s due to laser temperature and power drift caused by long-term wavelength scanning. Measurements for both indoor and outdoor concentration changes of CH4 and C2H6 were conducted. The reported single ICL based dual-gas sensor system has the advantages of reduced size and cost compared to two separate sensor systems.