Browsing by Author "Hu, Lien"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Light-induced off-axis cavity-enhanced thermoelastic spectroscopy in the near-infrared for trace gas sensing(Optical Society of Americ, 2021) Zheng, Kaiyuan; Zheng, Chuantao; Zheng, Chuantao; Hu, Lien; Guan, Gangyun; Ma, Yanming; Song, Fang; Zhang, Yu; Zhang, Yu; Wang, Yiding; Tittel, Frank K.A trace gas sensing technique of light-induced off-axis cavity-enhanced thermoelastic spectroscopy (OA-CETES) in the near-infrared was demonstrated by combing a high-finesse off-axis integrated cavity and a high Q-factor resonant quartz tuning fork (QTF). Sensor parameters of the cavity and QTF were optimized numerically and experimentally. As a proof-of-principle, we employed the OA-CETES for water vapor (H2O) detection using a QTF (Q-factor ∼12000 in atmospheric pressure) and a 10cm-long Fabry-Perot cavity (finesse ∼ 482). By probing a H2O line at 7306.75 cm-1, the developed OA-CETES sensor achieved a minimum detection limit (MDL) of 8.7 parts per million (ppm) for a 300 ms integration time and a normalized noise equivalent absorption (NNEA) coefficient of 4.12 × 10−9cm-1 WHz-1/2. Continuous monitoring of indoor and outdoor atmospheric H2O concentration levels was performed for verifying the sensing applicability. The realization of the proposed OA-CETES technique with compact QTF and long effective path cavity allows a class of optical sensors with low cost, high sensitivity and potential for long-distance and multi-point sensing.Item Long-distance in-situ methane detection using near-infrared light-induced thermo-elastic spectroscopy(Elsevier, 2021) Hu, Lien; Zheng, Chuantao; Zhang, Minghui; Zheng, Kaiyuan; Zheng, Jie; Song, Zhanwei; Li, Xiuying; Zhang, Yu; Wang, Yiding; Tittel, Frank K.A wavelength-locked light-induced thermo-elastic spectroscopy (WL-LITES) gas sensor system was proposed for long-distance in-situ methane (CH4) detection using a fiber-coupled sensing probe. The wavelength-locked scheme was used to speed the sensor response without scanning the laser wavelength across the CH4 absorption line. A small-size piezoelectric quartz tuning fork (QTF) with a wide spectral response range was adopted to enhance the photo-thermal signal. The optical excitation parameters of the QTF were optimized based on experiment and simulation for improving the signal-to-noise ratio of the LITES technique. An Allan deviation analysis was employed to evaluate the limit of detection of the proposed sensor system. With a 0.3 s lock-in integration time and a ∼ 100 m optical fiber, the WL-LITES gas sensor system demonstrates a minimum detection limit (MDL) of ∼ 11 ppm in volume (ppmv) for CH4 detection, and the MDL can be further reduced to ∼ 1 ppmv with an averaging time of ∼ 35 s. A real-time in-situ monitoring of CH4 leakage reveals that the proposed sensor system can realize a fast response (< 12 s) for field application.Item Near-infrared acetylene sensor system using off-axis integrated-cavity output spectroscopy and two measurement schemes(Optical Society of America, 2018) Zheng, Kaiyuan; Zheng, Chuantao; He, Qixin; Yao, Dan; Hu, Lien; Zhang, Yu; Wang, Yiding; Tittel, Frank K.For highly sensitive and accurate acetylene (C2H2) detection, a near-infrared (NIR) off-axis integrated-cavity output spectroscopy (OA-ICOS) sensor system based on an ultra-compact cage-based absorption cell was proposed. The absorption cell with dimensions of 10 cm × 8 cm × 6 cm realized a dense-pattern and an easily-aligned stable optical system. The OA-ICOS sensor system employed a 6cm-long optical cavity that was formed by two mirrors with a reflectivity of 99.35% and provided an effective absorption path length of ∼9.28 m. The performance of the C2H2 sensor system based on two measurement schemes, i.e. laser direct absorption spectroscopy (LDAS) and wavelength modulation spectroscopy (WMS) is reported. A NIR distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6523.88 cm−1. An Allan deviation analysis yielded a detection sensitivity of 760 parts-per-billion in volume (ppbv) for an averaging time of 304 s using the LDAS-based OA-ICOS. A detection sensitivity of 85 ppbv for an averaging time of 250 s was obtained using the WMS-based OA-ICOS, which was further improved by a factor of ~9 compared to the result obtained with the LDAS method. The proposed sensor system has the advantages of reduced size and cost with acceptable detection sensitivity, which is suitable for applications in trace gas sensing in harsh environments and weight-limited balloon-embedded observations.