Browsing by Author "Ben-Yakar, Adela"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
Item Kagome fiber based ultrafast laser microsurgery probe delivering micro-Joule pulse energies(The Optical Society, 2016) Subramanian, Kaushik; Gabay, Ilan; Ferhanoğlu, Onur; Shadfan, Adam; Pawlowski, Michal; Wang, Ye; Tkaczyk, Tomasz; Ben-Yakar, AdelaWe present the development of a 5 mm, piezo-actuated, ultrafast laser scalpel for fast tissue microsurgery. Delivery of micro-Joules level energies to the tissue was made possible by a large, 31 μm, air-cored inhibited-coupling Kagome fiber. We overcome the fiber’s low NA by using lenses made of high refractive index ZnS, which produced an optimal focusing condition with 0.23 NA objective. The optical design achieved a focused laser spot size of 4.5 μm diameter covering a 75 × 75 μm2 scan area in a miniaturized setting. The probe could deliver the maximum available laser power, achieving an average fluence of 7.8 J/cm2 on the tissue surface at 62% transmission efficiency. Such fluences could produce uninterrupted, 40 μm deep cuts at translational speeds of up to 5 mm/s along the tissue. We predicted that the best combination of speed and coverage exists at 8 mm/s for our conditions. The onset of nonlinear absorption in ZnS, however, limited the probe’s energy delivery capabilities to 1.4 μJ for linear operation at 1.5 picosecond pulse-widths of our fiber laser. Alternatives like broadband CaF2 crystals should mitigate such nonlinear limiting behavior. Improved opto-mechanical design and appropriate material selection should allow substantially higher fluence delivery and propel such Kagome fiber-based scalpels towards clinical translation.Item Two photon imaging probe with highly efficient autofluorescence collection at high scattering and deep imaging conditions(Optica Publishing Group, 2024) Camli, Berk; Andrus, Liam; Roy, Aditya; Mishra, Biswajit; Xu, Chris; Georgakoudi, Irene; Tkaczyk, Tomasz; Ben-Yakar, AdelaIn this paper, we present a 2-photon imaging probe system featuring a novel fluorescence collection method with improved and reliable efficiency. The system aims to miniaturize the potential of 2-photon imaging in the metabolic and morphological characterization of cervical tissue at sub-micron resolution over large imaging depths into a flexible and clinically viable platform towards the early detection of cancers. Clinical implementation of such a probe system is challenging due to inherently low levels of autofluorescence, particularly when imaging deep in highly scattering tissues. For an efficient collection of fluorescence signals, our probe employs 12 0.5 NA collection fibers arranged around a miniaturized excitation objective. By bending and terminating a multitude of collection fibers at a specific angle, we increase collection area and directivity significantly. Positioning of these fibers allows the collection of fluorescence photons scattered away from their ballistic trajectory multiple times, which offers a system collection efficiency of 4%, which is 55% of what our bench-top microscope with 0.75 NA objective achieves. We demonstrate that the collection efficiency is largely maintained even at high scattering conditions and high imaging depths. Radial symmetry of arrangement maintains uniformity of collection efficiency across the whole FOV. Additionally, our probe can image at different tissue depths via axial actuation by a dc servo motor, allowing depth dependent tissue characterization. We designed our probe to perform imaging at 775 nm, targeting 2-photon autofluorescence from NAD(P)H and FAD molecules, which are often used in metabolic tissue characterization. An air core photonic bandgap fiber delivers laser pulses of 100 fs duration to the sample. A miniaturized objective designed with commercially available lenses of 3 mm diameter focuses the laser beam on tissue, attaining lateral and axial imaging resolutions of 0.66 µm and 4.65 µm, respectively. Characterization results verify that our probe achieves collection efficiency comparable to our optimized bench-top 2-photon imaging microscope, minimally affected by imaging depth and radial positioning. We validate autofluorescence imaging capability with excised porcine vocal fold tissue samples. Images with 120 µm FOV and 0.33 µm pixel sizes collected at 2 fps confirm that the 300 µm imaging depth was achieved.Item Ultrafast laser surgery probe for sub-surface ablation to enable biomaterial injection in vocal folds(Springer Nature, 2022) Andrus, Liam; Jeon, Hamin; Pawlowski, Michal; Debord, Benoit; Gerome, Frederic; Benabid, Fetah; Mau, Ted; Tkaczyk, Tomasz; Ben-Yakar, AdelaCreation of sub-epithelial voids within scarred vocal folds via ultrafast laser ablation may help in localization of injectable therapeutic biomaterials towards an improved treatment for vocal fold scarring. Several ultrafast laser surgery probes have been developed for precise ablation of surface tissues; however, these probes lack the tight beam focusing required for sub-surface ablation in highly scattering tissues such as vocal folds. Here, we present a miniaturized ultrafast laser surgery probe designed to perform sub-epithelial ablation in vocal folds. The requirement of high numerical aperture for sub-surface ablation, in addition to the small form factor and side-firing architecture required for clinical use, made for a challenging optical design. An Inhibited Coupling guiding Kagome hollow core photonic crystal fiber delivered micro-Joule level ultrashort pulses from a high repetition rate fiber laser towards a custom-built miniaturized objective, producing a 1/e2 focal beam radius of 1.12 ± 0.10 μm and covering a 46 × 46 μm2 scan area. The probe could deliver up to 3.8 μJ pulses to the tissue surface at 40% transmission efficiency through the entire system, providing significantly higher fluences at the focal plane than were required for sub-epithelial ablation. To assess surgical performance, we performed ablation studies on freshly excised porcine hemi-larynges and found that large area sub-epithelial voids could be created within vocal folds by mechanically translating the probe tip across the tissue surface using external stages. Finally, injection of a model biomaterial into a 1 × 2 mm2 void created 114 ± 30 μm beneath the vocal fold epithelium surface indicated improved localization when compared to direct injection into the tissue without a void, suggesting that our probe may be useful for pre-clinical evaluation of injectable therapeutic biomaterials for vocal fold scarring therapy. With future developments, the surgical system presented here may enable treatment of vocal fold scarring in a clinical setting.Item Ultrafast laser surgery probe with a calcium fluoride miniaturized objective for bone ablation(Optical Society of Americ, 2021) Subramanian, Kaushik; Subramanian, Kaushik; Andrus, Liam; Andrus, Liam; Pawlowski, Michal; Wang, Ye; Tkaczyk, Tomasz; Ben-Yakar, Adela; Ben-Yakar, Adela; Ben-Yakar, AdelaWe present a miniaturized ultrafast laser surgery probe with improved miniaturized optics to deliver higher peak powers and enable higher surgical speeds than previously possible. A custom-built miniaturized CaF2 objective showed no evidence of the strong multiphoton absorption observed in our previous ZnS-based probe, enabling higher laser power delivery to the tissue surface for ablation. A Kagome fiber delivered ultrashort pulses from a high repetition rate fiber laser to the objective, producing a focal beam radius of 1.96 μm and covering a 90×90 μm2 scan area. The probe delivered the maximum available fiber laser power, providing fluences >6 J/cm2 at the tissue surface at 53% transmission efficiency. We characterized the probe’s performance through a parametric ablation study on bovine cortical bone and defined optimal operating parameters for surgery using an experimental- and simulation-based approach. The entire opto-mechanical system, enclosed within a 5-mm diameter housing with a 2.6-mm diameter probe tip, achieved material removal rates >0.1 mm3/min, however removal rates were ultimately limited by the available laser power. Towards a next generation surgery probe, we simulated maximum material removal rates when using a higher power fiber laser and found that removal rates >2 mm3/min could be attained through appropriate selection of laser surgery parameters. With future development, the device presented here can serve as a precise surgical tool with clinically viable speeds for delicate applications such as spinal decompression surgeries.