Durrani, Ahmad J.2009-06-042009-06-041993Du, Yong. "Seismic resistance of slab-column connections in non-ductile flat-plate buildings." (1993) Diss., Rice University. <a href="https://hdl.handle.net/1911/16619">https://hdl.handle.net/1911/16619</a>.https://hdl.handle.net/1911/16619In order to determine the seismic response of existing reinforced concrete non-ductile flat-plate buildings, four reinforced concrete slab-column connection subassemblies designed for gravity load only were built at half-scale of prototype structure, and tested at Ryon laboratory of the Rice University. Each specimen had two exterior and one interior connections. The variables included the presence of spandrel beam, magnitude of gravity load, and reinforcing arrangement. The behavior of entire subassemblies and the individual connections under the cyclic loading was studied in terms of failure mode, stiffness, ductility, shear capacity, and moment transfer capacity in the two loading directions. Based on the test results, a procedure to predict the flexural and shear strengths of the interior and exterior connections is recommended. A hysterestic model for non-ductile slab-column connections is proposed. This model reflects the unsymmetrical moment transfer behavior of non-ductile connections. Furthermore, the model is incorporated in a non-linear dynamic analysis program and a typical flat-plate building is analyzed to demonstrate the application of the analytical model.166 p.application/pdfengCopyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.Civil engineeringSeismic resistance of slab-column connections in non-ductile flat-plate buildingsThesisThesis C.E. 1993 Du