<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T12:19:59Z</responseDate><request verb="GetRecord" identifier="oai:repository.rice.edu:1911/64427" metadataPrefix="dim">https://repository.rice.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:repository.rice.edu:1911/64427</identifier><datestamp>2026-11-10T17:46:53Z</datestamp><setSpec>com_1911_8299</setSpec><setSpec>col_1911_13110</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Dick, Andrew J.</dim:field>
   <dim:field mdschema="dc" element="creator">Eason, R. Parker</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-07-03T22:49:43Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2012-07-03T22:49:43Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="created">2011-04</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation">Eason, R. Parker. "Optical Lever Measurement Accuracy for Off-Resonance
Atomic Force Microscopy." (2011) Master’s Thesis,  Rice University.  https://hdl.handle.net/1911/64427</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1911/64427</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="digital" lang="en_US">EasonR</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="callno">THESIS M.E. 2011 EASON</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">This research evaluates measurement accuracy in optical lever-based atomic force
microscopy (AFM) for off-resonance conditions and parameter variations. Under controlled
conditions and correct calibration, AFM provides researchers with the ability
to accurately observe and manipulate matter on the micro- and nano-scale. Accuracy
of imaging and nano-manipulation operations are directly correlated to the
accuracy with which the displacement of the probe is measured. The optical lever
method, a common displacement measurement technique employed in AFM, calculates
probe displacement based on a calibration that assumes a consistent response
profile throughout operation. Off-resonance excitation and tip-sample interaction
forces during intermittent contact mode AFM can alter this response profile. Standard
tapping-mode operation at the fundamental frequency is observed to be robust
to changes in effective stiffness, maintaining accurate measurements for all laser spot
positions considered. A nominal laser spot position between Xp = 0.5 and 0.6 is determined
to most accurately predict displacement for off-resonance excitation during
both free response and intermittent contact condit ions. Measurement accuracy for
off-resonance tapping- mode is more directly correlated to changes introduced to the
interaction force profile than choice of spot position.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">81 pp</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">eng</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.</dim:field>
   <dim:field mdschema="dc" element="subject">Mechanical engineering</dim:field>
   <dim:field mdschema="dc" element="subject">Materials science</dim:field>
   <dim:field mdschema="dc" element="title">Optical Lever Measurement Accuracy for Off-Resonance
Atomic Force Microscopy</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="type" qualifier="material">Text</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="department">Mechanical Engineering</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="discipline">Engineering</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="grantor">Rice University</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="level">Masters</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Master of Science</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>