<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T18:20:02Z</responseDate><request verb="GetRecord" identifier="oai:repository.rice.edu:1911/13220" metadataPrefix="dim">https://repository.rice.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:repository.rice.edu:1911/13220</identifier><datestamp>2026-11-13T17:05:14Z</datestamp><setSpec>com_1911_8299</setSpec><setSpec>col_1911_13110</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="creator">Goforth, Montgomery Bailey</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-05-09T17:58:20Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-05-09T17:58:20Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1987</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation">Goforth, Montgomery Bailey. "The Use of Surface Hot-Film Sensors in Dilute Polymer Flows." (1987) Master’s Thesis,  Rice University.  https://hdl.handle.net/1911/13220</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1911/13220</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="callno">THESIS M.E. 1987 GOFORTH</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">The purpose of this study was to assess the feasibility of using flush-mounted surface hot-film sensors in dilute polymer solutions to measure mean wall shear stress. Experiments were conducted using hot-film sensors mounted on the surface of a rotating disk. It is shown that a sensor calibration obtained in a pure water flow cannot be used directly to provide accurate skin friction measurements in a dilute polymer flow. However, the repeatability of the results suggests that a functional relation may exist between a sensor's calibration in water and in dilute polymer, thereby permitting precalibration of the sensor in pure water. It is also possible that reasonably consistent measurements may be obtained by precalibration of sensors in controlled polymer solutions.
Experiments were also conducted by injecting concentrated polymer solution (4000 ppm) into the boundary layer of the rotating disk. Drag reduction and hot-film performance comparable to that obtained with homogeneous dilute polymer solution was demonstrated.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">eng</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.</dim:field>
   <dim:field mdschema="dc" element="subject">Mechanical engineering</dim:field>
   <dim:field mdschema="dc" element="title">The Use of Surface Hot-Film Sensors in Dilute Polymer Flows</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="type" qualifier="material">Text</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="department">Mechanical Engineering</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="discipline">Engineering</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="grantor">Rice University</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="level">Masters</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Master of Science</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>