<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T10:03:33Z</responseDate><request verb="GetRecord" identifier="oai:repository.rice.edu:1911/105751" metadataPrefix="dim">https://repository.rice.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:repository.rice.edu:1911/105751</identifier><datestamp>2024-01-11T21:16:32Z</datestamp><setSpec>com_1911_8299</setSpec><setSpec>col_1911_13110</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Sabharwal, Ashutosh</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="committeeMember">Veeraraghavan, Ashok</dim:field>
   <dim:field mdschema="dc" element="creator">Kumar, Mayank</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2019-05-17T15:10:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2019-05-17T15:10:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="created">2018-05</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2018-04-20</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">May 2018</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="updated">2019-05-17T15:10:30Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation">Kumar, Mayank. &amp;quot;PulseCam: Design, development and clinical evaluation of a new multi-sensor camera-based blood perfusion imaging modality.&amp;quot; (2018) Diss.,  Rice University.  &amp;lt;a href=&amp;quot;https://hdl.handle.net/1911/105751&amp;quot;&amp;gt;https://hdl.handle.net/1911/105751&amp;lt;/a&amp;gt;.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1911/105751</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Blood perfusion is the flow of oxygen-rich blood to end organs and tissue through blood vessels. Measuring blood perfusion has widespread clinical applications, with examples including assessment of wounds and burns, perfusion monitoring in critical care, and monitoring blood flow into and out of a surgical site during and after surgery. However, conventional techniques to measure blood perfusion in clinics are either invasive or contact-based methods that can only measure perfusion at a single point on the skin surface. In this thesis, I designed PulseCam, a new camera-based, non-contact, and clinically-accurate blood perfusion imaging technique that can reliably measure spatial maps and temporal trends of blood perfusion over an entire organ. PulseCam combines video recordings of the skin surface with a reference pulse waveform recorded using a pulse oximeter. The pulse waveform helps in estimating blood perfusion maps robustly in the presence of sensor noise, motion artifacts and outliers in the video recording. I also utilized a new brightness-invariant optical flow algorithm which is better suited for blood perfusion imaging applications.

To evaluate PulseCam, I conducted two sets of experiments: (i) controlled blood flow occlusion experiments on healthy participants of varying skin tones in a lab setting, and (ii) a pilot clinical study on patients undergoing surgery in an operating room. Through the in-lab experiments, I demonstrated that PulseCam has higher sensitivity in detecting blood flow changes associated with partial occlusion compared to existing contact-based pulse-oximeter. Also, PulseCam could differentiate between no occlusion and venous occlusion scenarios, which is difficult to identify clinically. In the pilot clinical study, I used PulseCam to obtain spatio-temporal blood perfusion maps in an operationally challenging setting, that clearly demonstrate: (i) statistically significant difference in blood perfusion in any region of the palm before and after anesthesia induction, (ii) higher perfusion in the palm regions that receives blood directly from the radial and the ulnar artery. Hence, PulseCam can be used for blood perfusion imaging in a clinical setting as well as a low-cost point-of-care blood flow imaging tool.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">eng</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.</dim:field>
   <dim:field mdschema="dc" element="subject">Camera</dim:field>
   <dim:field mdschema="dc" element="subject">blood flow</dim:field>
   <dim:field mdschema="dc" element="subject">blood perfusion</dim:field>
   <dim:field mdschema="dc" element="subject">non-contact</dim:field>
   <dim:field mdschema="dc" element="subject">non-invasive</dim:field>
   <dim:field mdschema="dc" element="subject">perfusion imaging</dim:field>
   <dim:field mdschema="dc" element="subject">computer vision</dim:field>
   <dim:field mdschema="dc" element="subject">surgery</dim:field>
   <dim:field mdschema="dc" element="subject">critical care</dim:field>
   <dim:field mdschema="dc" element="subject">micro-circulations</dim:field>
   <dim:field mdschema="dc" element="subject">point-of-care</dim:field>
   <dim:field mdschema="dc" element="subject">medical device</dim:field>
   <dim:field mdschema="dc" element="subject">smart-phone</dim:field>
   <dim:field mdschema="dc" element="title">PulseCam: Design, development and clinical evaluation of a new multi-sensor camera-based blood perfusion imaging modality</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="type" qualifier="material">Text</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="department">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="discipline">Engineering</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="grantor">Rice University</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="level">Doctoral</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Doctor of Philosophy</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>